        2.67 CORRUGATED   | 
       
      
          | 
       
     
     | 
  
  
    
      
         | 
       
      
        | ROOFING: POSITIVE
        LOADS | 
       
      
        | SPAN | 
        Uniform 
        Loads, 
        PSF  | 
        SERIE | 
       
      
        | FR200 | 
        FR300 | 
        FR400 | 
       
      
        | SINGLE
         | 
        20 | 
        3'9" | 
        4'1" | 
        4'3" | 
       
      
        | TWO
         | 
        5'1" | 
        5'6" | 
        5'8" | 
       
      
        | THREE
         | 
        4'8" | 
        5'1" | 
        5'3" | 
       
      
        | SINGLE
         | 
        25 | 
        3'6" | 
        3'10" | 
        3'11" | 
       
      
        | TWO
         | 
        4'8" | 
        5'2" | 
        5'3" | 
       
      
        | THREE
         | 
        4'4" | 
        4'9" | 
        4'10" | 
       
      
        | SINGLE
         | 
        30 | 
        3'3" | 
        3'7" | 
        3'8" | 
       
      
        | TWO
         | 
        4'5" | 
        4'10" | 
        4'11" | 
       
      
        | THREE
         | 
        4'1" | 
        4'5" | 
        4'7" | 
       
      
        | SINGLE
         | 
        35 | 
        3'1" | 
        3'5" | 
        3'6" | 
       
      
        | TWO
         | 
        4'2" | 
        4'7" | 
        4'8" | 
       
      
        | THREE
         | 
        3'10" | 
        4'3" | 
        4'4" | 
       
      
        | SINGLE
         | 
        40 | 
        3'0" | 
        3'3" | 
        3'4" | 
       
      
        | TWO
         | 
        3'11" | 
        4'5" | 
        4'6" | 
       
      
        | THREE
         | 
        3'8" | 
        4'1" | 
        4'2" | 
       
      
        | SINGLE
         | 
        50 | 
        2'9" | 
        3'0" | 
        3'1" | 
       
      
        | TWO
         | 
        3'2" | 
        4'1" | 
        4'2" | 
       
      
        | THREE
         | 
        3'5" | 
        3'9" | 
        3'10" | 
       
     
     | 
  
  
     | 
  
  
    
      
         | 
       
      
        ROOFING: NEGATIVE
        LOADS  
        Fasteners required at every other corrugation | 
       
      
        | SPAN | 
        Uniform 
        Loads, 
        PSF  | 
        SERIE | 
       
      
        | FR200 | 
        FR300 | 
        FR400 | 
       
      
        | SINGLE
         | 
        20 | 
        3'9" | 
        4'1" | 
        4'3" | 
       
      
        | TWO
         | 
        5'1" | 
        5'6" | 
        5'8" | 
       
      
        | THREE
         | 
        4'8" | 
        5'1" | 
        5'3" | 
       
      
        | SINGLE
         | 
        25 | 
        3'6" | 
        3'10" | 
        3'11" | 
       
      
        | TWO
         | 
        4'8" | 
        5'2" | 
        5'3" | 
       
      
        | THREE
         | 
        4'4" | 
        4'9" | 
        4'10" | 
       
      
        | SINGLE
         | 
        30 | 
        3'3" | 
        3'7" | 
        3'8" | 
       
      
        | TWO
         | 
        4'5" | 
        4'10" | 
        4'11" | 
       
      
        | THREE
         | 
        4'1" | 
        4'5" | 
        4'7" | 
       
      
        | SINGLE
         | 
        35 | 
        3'1" | 
        3'5" | 
        3'6" | 
       
      
        | TWO
         | 
        4'2" | 
        4'7" | 
        4'8" | 
       
      
        | THREE
         | 
        3'10" | 
        4'3" | 
        4'4" | 
       
      
        | SINGLE
         | 
        40 | 
        3'0" | 
        3'3" | 
        3'4" | 
       
      
        | TWO
         | 
        3'11" | 
        4'5" | 
        4'6" | 
       
      
        | THREE
         | 
        3'8" | 
        4'1" | 
        4'2" | 
       
      
        | SINGLE
         | 
        50 | 
        2'9" | 
        3'0" | 
        3'1" | 
       
      
        | TWO
         | 
        3'2" | 
        4'1" | 
        4'2" | 
       
      
        | THREE
         | 
        3'5" | 
        3'9" | 
        3'10" | 
       
     
     | 
  
  
    
      
         | 
       
      
        SIDING: WIND LOADS  
        Fasteners required at every other corrugation | 
       
      
        | SPAN | 
        Uniform 
        Loads, 
        PSF  | 
        SERIE | 
       
      
        | FR200 | 
        FR300 | 
        FR400 | 
       
      
        | SINGLE
         | 
        20 | 
        4'9" | 
        5'2" | 
        5'4" | 
       
      
        | TWO
         | 
        6'5" | 
        7'0" | 
        7'2" | 
       
      
        | THREE
         | 
        5'11" | 
        6'5" | 
        6'7" | 
       
      
        | SINGLE
         | 
        25 | 
        4'5" | 
        4'10" | 
        4'11" | 
       
      
        | TWO
         | 
        5'11" | 
        6'6" | 
        6'8" | 
       
      
        | THREE
         | 
        5'6" | 
        6'0" | 
        6'2" | 
       
      
        | SINGLE
         | 
        30 | 
        4'2" | 
        4'7" | 
        4'8" | 
       
      
        | TWO
         | 
        5'3" | 
        6'1" | 
        6'3" | 
       
      
        | THREE
         | 
        5'2" | 
        5'7" | 
        5'9" | 
       
      
        | SINGLE
         | 
        35 | 
        3'11" | 
        4'4" | 
        4'5" | 
       
      
        | TWO
         | 
        4'6" | 
        5'10" | 
        5'11" | 
       
      
        | THREE
         | 
        4'11" | 
        5'4" | 
        5'6" | 
       
      
        | SINGLE
         | 
        40 | 
        3'9" | 
        4'1" | 
        4'3" | 
       
      
        | TWO
         | 
        3'11" | 
        5'6" | 
        5'8" | 
       
      
        | THREE
         | 
        4'6" | 
        5'1" | 
        5'3" | 
       
      
        | SINGLE
         | 
        50 | 
        3'6" | 
        3'10" | 
        3'11" | 
       
      
        | TWO
         | 
        3'2" | 
        4'9" | 
        4'9" | 
       
      
        | THREE
         | 
        3'7" | 
        4'9" | 
        4'10" | 
       
     
     | 
  
  
    | Contact Enduro for SERIES FM
    Loads/Span Data | 
  
  
     | 
  
  
    Load/Span Tables are based on full
    scale tests that consider three design parameters:
      - Critical bending moment at actual
        panel failure 
 
      - Flexural stiffness 
 
      - Pullover force per fastener of the
        panel section. 
 
     
    Table values are based upon: 
      - Roofing: Deflection l/60, FOS
        2.5+, 1.88- 
 
      - Siding: Deflection L/30 FOS
        1.88 
 
     
     | 
  
  
     | 
  
  
    | 
     | 
  
  
     | 
  
  
    | 
     | 
  
  
     | 
  
  
    The load/span tables shown in this
    Guide are derived  large scale tests using full panels to simulate actual service
    conditions (at a reference temperature of 77° F). These tests include two span vacuum box
    test and three point load tests. 
     
    Each span shown in the load/span tables represents the most conservative span derived when
    the panel is assessed using the following parameters:  
     
    Design Parameters 
      - Critical bending moment at actual
        panel failure; 
 
      - Flexural stiffness factor, EI, (where
        E is the flexural 
 
        modulus of elasticity and I is the moment of inertia of 
        the panel section); and  
      - Pullover force resistance per
        fastener. 
 
     
     | 
  
  
    | 
     | 
  
  
     | 
  
  
    The load/span tables shown in this
    Guide are developed using the following maximum deflections limits and Factors of Safety
    (FOS), unless otherwise noted:  
     
    Panel Roofing:  
    Positive Loads: Deflection: L/60, FOS:2.5  
    Negative Loads: Deflection: L/60, FOS: 1.88  
    Panel Siding:  
    Wind Loads: Deflection: L/30, FOS:1.88  
    Roof Deck: 
    Dead + Live Loads: Deflection: L/180, FOS:2.5 Uplift Loads: Deflection: L/18000, FOS:1.88  
     
    The load/span tables are to be used as a guide only as specific environmental conditions
    are not considered.  
     
    Specific applications should be verified by a registered Professional Engineer.  |